EasyManua.ls Logo

Telit Wireless Solutions ME910G1 - ATS12 - Escaper Prompt Delay

Telit Wireless Solutions ME910G1
1039 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 137 of 1039 2021-09-23
Not Subject to NDA
3.2.3.8. ATS12 - Escaper Prompt Delay
The command manages the prompt delay between two different escape characters.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Specific profile
No
-
2
ATS12=<time>
Set command sets:
5. the minimum period, before receipt of the first character of the
three escape character sequence, during which no other character
has to be detected in order to accept it as valid first character;
6. the maximum period allowed between receipt of first or second
character of the three escape character sequence and receipt of
the next;
7. the minimum period, after receipt of the last character of the three
escape character sequence, during which no other character has to
be detected in order to accept the escape sequence as a valid one.
Parameter:
Name
Type
Default
Description
<time>
integer
50
delay expressed in fiftieth of a second
Value:
2÷255
:
expressed in fiftieth of a second
The minimum period S12 has to pass after CONNECT result code
too, before a received character is accepted as valid first character
of the three escape character sequence.
ATS12?
Read command returns the current value of S12 parameter.