ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 897 of 1039 2021-09-23
Not Subject to NDA
3.24.5. AT#MQCFG2 - Configure Additional MQTT Parameters
This command sets the optional connection parameters for the selected MQTT client.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
No
No
-
2
AT#MQCFG2=<instanceNumber>,<keepAlive>,<cleanSession>
Parameters:
Name
Type
Default
Description
<instanceNumber>
integer
N/A
selects the client instance. The
list of available clients is
obtained with AT#MQEN? or the
read command.
Value:
1÷maxClients
:
client instance range. To know
maxClients value use test
command
<keepAlive>
integer
20
timeout of periodic packet to
keep connection open
Value:
1÷3600
:
timeout expressed in sec
<cleanSession>
integer
1
Indicates whether a persistent
connection is required. Without
a persistent connection, when
the client is offline all
information and messages that
are queued from a previous
persistent session are lost.
Values:
1
:
clean session