EasyManuals Logo

Telit Wireless Solutions ME910G1 User Manual

Telit Wireless Solutions ME910G1
1039 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #863 background imageLoading...
Page #863 background image
ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 863 of 1039 2021-09-23
Not Subject to NDA
3.23.5. AT+M2M - Enable/disable M2M Application execution
This command enable/disable the M2M Application execution start mode.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Auto
No
-
2
AT+M2M=<mode>[,<delay>]
Set command sets the M2M Application start mode. After issuing the AT
command, the module automatically restart.
Parameters:
Name
Type
Default
Description
<mode>
integer
1
M2M application execution start mode
Values:
0
:
AppZone engine does not start at the next reboot
1
:
AppZone engine starts at the next reboot without
delay. Only apps with AT#M2MRUN=1 will start after
reboot, with their specific delay setting.
4
:
AppZone engine starts at the next reboot using the
delay set by <delay> parameter, if missing is used the
default value 10.
<delay>
integer
0
M2M application execution start time-out
expressed in seconds.
Parameter <delay> is used only if
parameter <mode> is set to 4.
Values:
0
:
no delay for AppZone engine to start
10÷60
:
delay for AppZone engine to start. During this
waiting time an AT command on the serial/USB

Table of Contents

Other manuals for Telit Wireless Solutions ME910G1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ME910G1 and is the answer not in the manual?

Telit Wireless Solutions ME910G1 Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelME910G1
CategoryWireless modules
LanguageEnglish

Related product manuals