3.3.6. AT+CPWD - Change Facility Password
This command changes the password for the facility lock function defined by command
Facility Lock +CLCK command.
3GPP TS 27.007
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
Other
Yes
180 s
2
AT+CPWD=<fac>,<oldpwd>,<newpwd>
Execution command changes the password for the facility lock function
defined by command Facility Lock +CLCK command.
Parameters:
Name
Type
Default
Description
<fac>
string
N/A
facility lock function.
Values:
"SC"
:
SIM (PIN request)
"P2"
:
SIM PIN2
<oldpwd>
string
-
it shall be the same as password specified
for the facility from the ME user interface
or with command +CPWD.
<newpwd>
string
-
new password.
Parameter <oldpwd> is the old password while <newpwd> is the
new one.
The password can be changed only if PIN request is enabled (see
+CLCK command).