EasyManua.ls Logo

Telit Wireless Solutions ME910G1 - AT#CCLK - Clock Management

Telit Wireless Solutions ME910G1
1039 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 493 of 1039 2021-09-23
Not Subject to NDA
3.8.8. AT#CCLK - Clock Management
The command is related to real time clock management.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Auto
No
-
2
AT#CCLK=<time>
Set command sets the real-time clock of the module.
Parameter:
Name
Type
Default
Description
<time>
string
N/A
Current time as quoted
string in the format:
"yy/MM/dd,hh:mm:ss±zz,d"
Values:
yy
:
year (two last digits are mandatory), range is 00..99
MM
:
month (two digits are mandatory), range is 01..12
dd
:
day (two digits are mandatory) The range for dd(day)
depends either on the month and on the year, it
refers to. Available ranges are: (01..28) (01..29)
(01..30) (01..31). Trying to enter an out of range value
will raise an ERROR message.
hh
:
hour (two digits are mandatory), range is 00..23
mm
:
minute (two digits are mandatory), range is 00..59
ss
:
seconds (two digits are mandatory), range is 00..59
±zz
:
time zone (indicates the difference, expressed in
quarter of an hour, between the local time and GMT;
two digits are mandatory), range is: -96..+96