3.15.13. AT#SLUDP - Socket Listen UDP
This command opens/closes a socket listening for an incoming UDP connection on a
specified port.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
Other
No
-
2
AT#SLUDP=<connId>,<listenState>,<listenPort>
Execution command opens/closes a socket listening for an incoming UDP
connection on a specified port.
Parameters:
Name
Type
Default
Description
<connId>
integer
N/A
socket connection identifier
Value:
1÷conMax
:
socket connection identifier. conMax
value is returned by test command
<listenState>
integer
0
indicates the action that will be
performed
Values:
0
:
closes socket listening
1
:
starts socket listening
<listenPort>
integer
1
local listening port
Value:
1÷65535
:
available port numbers