EasyManua.ls Logo

Telit Wireless Solutions ME910G1 - Page 719

Telit Wireless Solutions ME910G1
1039 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 719 of 1039 2021-09-23
Not Subject to NDA
Value:
1÷65535
:
port
<updModClock
>
intege
r
N/A
update mode
Values:
0
:
no update module clock
1
:
update module clock
<timeout>
intege
r
N/A
waiting timeout for server response in
seconds. Due to internal algorithm the total
timeout will be up to 3*<timeout>.
Value:
1÷10
:
waiting timeout for server response in seconds
<timeZone>
string
0
Time Zone: indicates the difference,
expressed in quarter of an hour, between the
local time and GMT.
Value:
-47÷48
:
Time Zone
Additional info:
Intermediate response parameter.
Name
Type
Default
Description
<time>
string
-
current time as quoted string in the format:
"yy/MM/dd,hh:mm:ss±zz"
In case of error, the command returns the following error message:
+CME ERROR: <err>
Parameter <err> can be either numeric or verbose (see +CMEE). The
available values are reported in the table: