3.2.3.9. ATS25 - Delay to DTR Off
The command manages the amount of time that the device will ignore the DTR.
ATS25=<time>
Set command defines the amount of time, in hundredths of second, that
the device will ignore the DTR for taking the action specified by command
&D.
Parameter:
expressed in hundredths of a second
expressed in hundredths of a second
The delay is effective only if its value is greater than 5. To be
recognized as valid, the DTR transition must be greater than S25.
Low values could require a transition increased of a factor 1.5 to be
correctly handled (e.g., to be sure that S25=5 works, use a DTR
toggle of 75ms to be detected).
In power saving (e.g. +CFUN=5 with DTR low) DTR must be off at
least 3 seconds for taking the action specified by command &D,
independently of S25 parameter.
ATS25?