3.24.3. AT#MQDISC - Log Out and Disconnect from the MQTT Broker
This command performs the logout and disconnection from to the MQTT broker.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
No
No
-
2
AT#MQDISC=<instanceNumber>
Disconnects gracefully from the MQTT broker, then closes the network
connection
Parameter:
Name
Type
Default
Description
<instanceNumber>
integer
N/A
selects the client instance to
activate or deactivate
Value:
1÷maxClients
:
client instance range. To know
maxClients value use test
command
AT#MQDISC=?
Test command reports the available range of values for parameters.
AT#MQDISC=1
OK
Test command
AT#MQDISC=?
#MQDISC: (1-maxClients)
OK