ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 168 of 1039 2021-09-23
Not Subject to NDA
3.2.4.15. AT#E2ESC - Escape Sequence Guard Time
This set command sets a guard time in seconds for the escape sequence in PS to be
considered a valid one, and return to on-line command mode.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
Auto
No
-
2
AT#E2ESC=[<gt>]
Parameter:
Name
Type
Default
Description
<gt>
string
0
sets a guard time in seconds
Values:
0
:
guard time is defined by S12 command
1÷10
:
guard time in seconds. It overrides the one set with
S12 command
AT#E2ESC?
Read command returns current value of the escape sequence guard time,
in the format:
#E2ESC: <gt>
AT#E2ESC=?
Test command returns the range of supported values for parameter <gt>.