ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 152 of 1039 2021-09-23
3.2.4.6. AT&D - Data Terminal Ready (DTR) Control
This set command configures the behavior of the module according to the DTR control
line transitions (RS232).
defines the module behavior according
to the DTR control line transitions
module ignores DTR control line transitions
when the module is connected, the high to low transition
of DTR line sets the module in command mode, the
current connection is not closed
when the module is connected, the high to low transition
of DTR line sets the module in command mode and the
current connection is closed
C108/1 operation is enabled
C108/1 operation is disabled
If AT&D2 has been issued, and the DTR line has been tied Low,
auto-answering is inhibited and it is possible to answer only
issuing command ATA.
If parameter is omitted, the command has the same behavior of
AT&D0.