EasyManuals Logo

Telit Wireless Solutions ML865G1 Reference Guide

Telit Wireless Solutions ML865G1
1039 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #471 background imageLoading...
Page #471 background image
ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 471 of 1039 2021-09-23
Not Subject to NDA
3.7.6. AT#CPBGW - Write Group Entry
Set command writes the name of a phonebook group <text> in the Grouping information
Alpha String (GAS) USIM file in a specified location number <index>.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
No
No
-
2
AT#CPBGW=<index>,<text>
Parameters:
Name
Type
Default
Description
<index>
integer
-
number of the record in the GAS file to be
written; value ranges from 1 to the number
of records of the GAS file, that varies from
USIM to USIM
<text>
string
-
text to be stored in the record
If record number <index> already exists, it will be overwritten
AT#CPBGW=?
Test command returns location range supported by the current storage as
a compound value, and maximum length of <text> field. The format is:
+CPBGW: (list of supported <index>s),<tlength>
Additional info:
Parameter:
Name
Type
Default
Description

Table of Contents

Other manuals for Telit Wireless Solutions ML865G1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ML865G1 and is the answer not in the manual?

Telit Wireless Solutions ML865G1 Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelML865G1
CategoryWireless modules
LanguageEnglish

Related product manuals