ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 282 of 1039 2021-09-23
Not Subject to NDA
3.3.38. AT#RFSTS - Read Current Network Status
Command reads current network status.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
No
No
-
2
AT#RFSTS
Execution command returns the current network status. The format of the
returned message is according to the network on which the module is registered.
GSM network
#RFSTS:<PLMN>,<ARFCN>,<RSSI>,<LAC>,<RAC>,<TXPWR>,<MM>,<RR>,<NOM>,
<CID>, <IMSI>,<NetNameAsc>,<SD>,<ABND>
Parameters
Description
<PLMN>
Country code and operator code (MCC, MNC)
<ARFCN>
GSM Assigned Radio Channel
<RSSI>
Received Signal Strength Indication
<LAC>
Localization Area Code
<RAC>
Routing Area Code
<TXPWR>
Tx Power
Parameter/values
Description
<MM>
Mobility Management state (for debug purpose only)
0
NULL
3
LOCATION UPDATING INITIATED
5
WAIT FOR OUTGOING MM CONNECTION
6
CONNECTION ACTIVE
7
IMSI DETACH INITIATED
8
PROCESS CM SERVICE PROMPT
9
WAIT FOR NETWORK COMMAND
10
LOCATION UPDATE REJECTED
13
WAIT FOR RR CONNECTION LOCATION UPDATE

Table of Contents

Other manuals for Telit Wireless Solutions ML865G1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ML865G1 and is the answer not in the manual?

Telit Wireless Solutions ML865G1 Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelML865G1
CategoryWireless modules
LanguageEnglish

Related product manuals