ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 551 of 1039 2021-09-23
Not Subject to NDA
3.10.13. AT#TEMPMON - Temperature Monitor
This command is used to retrieve internal temperature information of the module.
[1] Hardware User's Guide of the used module
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Auto
No
-
2
AT#TEMPMON=<mod>[,<urcMode>[,<action>[,<hystTime>[,<GPIO>]]]]
Set command sets the internal temperature monitoring mode of the
module, reads it, and enables/disables/triggers the presentation of the
temperature monitoring message, that can be respectively an URC or an
intermediate message according to the selected mode.
#TEMPMEAS: <level>,<value>
The temperature monitoring message parameters are described in the
Unsolicited fields section.
Parameters:
Name
Type
Default
Description
<mod>
integer
0
select the temperature monitoring
mode.
Values:
0
:
only if <mod>=0 optional parameters of the
command have meaning
1
:
triggers the measurement of the module internal
temperature, reporting the result using the format
shown above
<urcMode>
integer
0
URC presentation mode

Table of Contents

Other manuals for Telit Wireless Solutions ML865G1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ML865G1 and is the answer not in the manual?

Telit Wireless Solutions ML865G1 Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelML865G1
CategoryWireless modules
LanguageEnglish

Related product manuals