EasyManuals Logo

Telit Wireless Solutions ML865G1 Reference Guide

Telit Wireless Solutions ML865G1
1039 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #532 background imageLoading...
Page #532 background image
ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 532 of 1039 2021-09-23
Not Subject to NDA
3.10.4. AT#ALARMPIN - Alarm Pin Configuration
This command allows to configure the ALARM Pin.
[1] Hardware User's Guide of the used module
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Auto
No
-
2
AT#ALARMPIN=<pin>
Set command allows to set a GPIO pin as ALARM pin.
Configuring a GPIO pin as ALARM pin is equivalent to setting it up with the
ALT2 alternate function. Therefore, a GPIO pin can be configured as
ALARM pin also through the #GPIO command. To have information on
GPIO pins refer to document [1].
Parameter:
Name
Type
Default
Description
<pin>
integer
0
GPIO pin number.
Max is the number of GPIO pins provided by
the module. For information on the available
GPIO pins use the test command.
Values:
0
:
no ALARM pin set
1÷Max
:
GPIO pin number
AT#ALARMPIN?
Read command returns the current value of the parameter <pin> in the
format:

Table of Contents

Other manuals for Telit Wireless Solutions ML865G1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ML865G1 and is the answer not in the manual?

Telit Wireless Solutions ML865G1 Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelML865G1
CategoryWireless modules
LanguageEnglish

Related product manuals