ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 368 of 1039 2021-09-23
<cmdType>=34 (GET INKEY proactive command)
#STGI response format:
#STGI: 34,<cmdDetails>,<text>
a bit mask where each bit position,
according to its value, has a specific
meaning:
bit 0:
0 - digits only (0-9, *, # and +)
1 - alphabet set
bit 1:
0 - SMS default alphabet (GSM
character set)
1 - UCS2 alphabet
bit 2:
0 - character sets defined by bit 0
and bit 1 are enabled
1 - character sets defined by bit 0
and bit 1 are disabled and the
"Yes/No" response is requested
bits 3-6:
0
bit 7:
0 - no help information available
1 - help information available
<cmdType>=35 (GET INPUT proactive command)
#STGI response format:
#STGI:
35,<cmdDetails>,<text>,<responseMin>,<responseMax>[,<defaultText>]