ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 519 of 1039 2021-09-23
operate up zone temperature
threshold clear. Default value 93 °C.
operate up zone temperature
threshold. Default value 100 °C.
operate up zone action info. Default
value 3.
extreme up zone temperature
threshold clear. Default value 98 °C.
extreme up zone temperature
threshold. It has only one valid value:
528 °C. See note.
extreme up zone action info. Default
value 3.
The temperature correctly set are saved in a configuration file in the
module file system.
etlz_clr: extreme low zone threshold clear is enforced to have value of -
273 °C. Module doesn't operate in such temperature, but this value is
logically set to define clearly 'thermal state' to temperatures below -40 °C.
etuz: extreme up zone threshold is enforced to have value of 528 °C.
Module doesn't operate in such temperature, but this value is logically set
to define clearly 'thermal state' to temperatures above 100 °C.
The user must not set <otnz_act_in>=5 (Operate normal zone). This comes
to prevent setting "automatic shutdown" by mistake to the normal
operating temperature range. Error will be received as a response:
+CME ERROR: operation not supported
AT#TEMPCFG?
Read command reports the current parameter setting for #TEMPCFG command
in the format: