EasyManuals Logo

Telit Wireless Solutions ML865G1 Reference Guide

Telit Wireless Solutions ML865G1
1039 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #84 background imageLoading...
Page #84 background image
ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 84 of 1039 2021-09-23
Not Subject to NDA
mode (after +++ was entered), all URCs stored in the
buffer will be output
<keyp>
integer
0
keypad event
reporting
Value:
0
:
No keypad event reporting
<disp>
integer
0
display event
reporting
Value:
0
:
no display event reporting
<ind>
integer
0
indicator event
reporting
Values:
0
:
no indicator event reporting
2
:
indicator event reporting
<bfr>
integer
0
TA buffer clearing
Values:
0
:
TA buffer of unsolicited result codes is cleared when
<mode> 1..3 is entered
1
:
TA buffer of unsolicited result codes is flushed to the
TE when <mode> 1...3 is entered (OK response shall
be given before flushing the codes)
Sending of URCs in the case of key pressings or display changes
are currently not implemented.
After +CMER has been switched on with e.g. AT+CMER=2,0,0,2
command (i.e. <bfr> is 0), URCs for all registered indicators will be
issued only first time, if previous <mode> was 0, for backward
compatibility. Values shown by the indicators will be current

Table of Contents

Other manuals for Telit Wireless Solutions ML865G1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ML865G1 and is the answer not in the manual?

Telit Wireless Solutions ML865G1 Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelML865G1
CategoryWireless modules
LanguageEnglish

Related product manuals