B-26 Micro-Tech 9101/9201 Reference Manual, Rev J Thermo Fisher Scientific
scale
Stamped weight of calibration weight(s).
Stamped at each handle end.
*Maximum is load cell size multiplied by
number of load cells.
7 Weight Cal constant Calculated (or factored) accumulated weight
at end of simulated static weight calibration
The system can be programmed to prompt
you when the next calibration is due. If you
do not want this option, confirm the default 0
days interval; otherwise enter the number of
days.
If a non-zero value is entered, an alarm
appears after the time is elapsed. The alarm
can only be cleared after a calibration check
Last
Next
This scroll displays the date of the last
calibration and the expected date of the next
one, based on the entry in the previous
R-CAL
Correction factor for Rcal calibration when
span is derived from other calibration
Material FACTOR
CHAINS
0.00% (-99.99 - 99.99) Correction factor for Chain calibration when
span is derived from other calibration
standard
WEIGHT
Correction factor for Static Weights
calibration when span is derived from other
calibration standard
Either a full length (1) or a shorter time test
duration (2)
duration
DUR
Choose belt length
measurement
revolution.
Measured length of entire belt length
marks on belt.
belt revolutions to be
timed
Required belt revolutions to achieve
minimum test time