C-10 Micro-Tech 9101/9201 Reference Manual, Rev J Thermo Fisher Scientific
Register Name Description
See Command Table on page C-19.
Model ID
Batch Number
The number of the currently running load out or the number of the last finished
one. The integrator automatically increments the batch number when a new batch
Batch Deviation
The maximum acceptable deviation from the batch set point. Usually entered by
the user.
AZ Deviation The current value of auto-zero deviation.
Zero Number Indicate the zero in use in the scale.
Zero Reference The current value of the zero reference.
Set/Res Out #
It is a variable that allows the master to directly handle the spare digital outputs of
the Micro-Tech. There are 5 registers in the write group so the master has the
capability to Set or Reset up to a maximum of five outputs simultaneously.
The least significant byte of the word is used to select the number of the physical
output.
The most significant byte is used to set/reset the output; set the first bit to 1 for
“ON”, and to 0 for “OFF”.
If the content of this byte is 0, the command is ignored.
WARNING : The Micro-Tech does not control
if the output the master is
setting/resetting is a spare or not; if the master tries to change the state of
a not-spare output, a conflict could happen
.
Set/Res Out #
Set/Res Out #
Set/Res Out #
Set/Res Out #
Indicate the span in use in the scale.
Scale Capacity
The scale capacity of the scale. Entered by the user at first start up, should never
be altered.
Speed Capacity
The speed capacity of the integrator. Entered or acquired at first start up, should
never be altered.
Load Cell Capacity
The load-cell capacity of the integrator. Entered at first start up, should never be
altered.
Rate
The instantaneous rate in engineering units as currently displayed on the Run
screen.
The instantaneous belt load in engineering units.
Speed The instantaneous belt speed in engineering units.
Master Total The current value of the master totalizer of the Micro-Tech.
Reset Total
The current value of the reset totalizer of the Micro-Tech. Reset total can be
zeroed by writing zero to this register.
Operator Total
The current value of the operator totalizer of the Micro-Tech. Operator total can be
zeroed by writing zero to this register.
Batch Total
The current contents of the Load Out totalizer. Usually read at end of batch to
check the result of the Load Out. This register is automatically cleared when a new
Batch Setpoint
The set point for the current or the next batch (Load Out). Usually entered or
downloaded by the user. The value is updated only when a batch is started.
Batch Preset
The pre-set point for the current or the next batch (load out). Set by the user.
Defines when the rate is lowered to increase batch accuracy.
The set point of the pre-act for the current or the next Load Out. Entered or