203
OPUS Projektor Manual
Variables
i.MX 35
i.MX 6 A-Series
i.MX 6 B-Series
ISOBUS
No
Yes
No
Yes
@DigitalOutputFailure02
Shows if digital output 2 has detected a failure (set value != loopback value)
If the value of @DigitalOutput0x and @DigitalOutputLoopback0x is not the same, this
variable signals the failure.
0: No failure
1: Failure detected
Index
Subin
dex
Stora
ge
Type
Lengt
h
Acces
s
Type
Rema
nent
Force
Writin
g
Initiali
ze as
Invali
d
Defaul
t
Value
Min
Value
Max
Value
0x20a
0
0x21
Unsign
ed
8 Bit
Read
Only
disabl
ed
disabl
ed
enable
d
0
0
255
Supported on Platforms:
i.MX 35
i.MX 6 A-Series
i.MX 6 B-Series
ISOBUS
No
Yes
No
Yes
@DigitalOutputFailure03
Shows if digital output 3 has detected a failure (set value != loopback value)
If the value of @DigitalOutput0x and @DigitalOutputLoopback0x is not the same, this
variable signals the failure.
0: No failure
1: Failure detected
Index
Subin
dex
Stora
ge
Type
Lengt
h
Acces
s
Type
Rema
nent
Force
Writin
g
Initiali
ze as
Invali
d
Defaul
t
Value
Min
Value
Max
Value
0x20a
0
0x22
Unsign
ed
8 Bit
Read
Only
disabl
ed
disabl
ed
enable
d
0
0
255
Supported on Platforms:
i.MX 35
i.MX 6 A-Series
i.MX 6 B-Series
ISOBUS
No
Yes
No
Yes
Display Backlight
@DisplayBacklight_NoOfEntries
"Number of entries in this group"
Index
Subin
dex
Stora
ge
Type
Lengt
h
Acces
s
Type
Rema
nent
Force
Writin
g
Initiali
ze as
Invali
d
Defaul
t
Value
Min
Value
Max
Value

Table of Contents