OPUS Projektor Manual
OPUS devices update manual
14.3.5
Update via partition
It is possible to update OS and application without a USB stick (not valid for ISO-V2).
For this, the files have to be put into a special folder that might have to be created at first.
For A3/A6G1: /opt/var/update
This folder might have to be created first:
mkdir /opt/var/update
For A6g2/A8/B3/B4: /var/shadow/update (without update images or uImage files)
For A6g2/A8/B3/B4 you can also put a uImage file into: /var/shadow/boot
To use the partition, it needs to be remounted as read-write first:
mounto remount,rw /var/shadow
14.4
Additional information
14.4.1
Connecting to the serial console
You can connect to the serial console of the device to change the boot logo, read debug and
error messages and copy files and folders.
You need to connect your computer to the RS232 interface of the device, either directly with
an RS232 cable, if your computer has the according connector, or with a RS232 <-> USB
cable.