Trango Systems, Inc. GigaPlus User Manual Rev 3.1 142
Reset will not reset ipconfig, use “reset
ipconfig” to reset the ip address settings.
license
N/A
None
N/A
license_speed
<1-2> <key>
N/A
license_tdm
key
N/A
link_history
N/A
N/A
linktest
duration <1-99>
Default 1 (if duration not entered by
user)
loglevel
<0: Setting, 1: Event, 2: Status>
0,1
loopback
<dig | if | rf_gen | rf_refl | off>
Off
loopback_auto
N/A
N/A
model
N/A
No defaults, read directly from the
IDU/ODU
mse
duration <1-99>
Default 1 (if duration not entered by
user)
oduled
<on|off>
On
odupower
<on|off>
Off
odurxagc
<on|off>
Off
opmode
<on|off>
Off
passwd
<passwd> <confirm_passwd> (8char)
trango
port
<eth > <1-4> <auto_nego, duplex,
enable, maxrate, pause, priority,
speed
All 4 ports configured in the Auto-Neg
Mode
power
0-30
10dBm
prompt
Character string
N/A
qos
priority<0-7>, dscp_weight <1-15>,
mode<strict/WRR>
1 to 1 COS mapping, strict mode
Priority 0: COS Queue = 0
Priority 1: COS Queue = 1
Priority 2: COS Queue = 2
Priority 3: COS Queue = 3
Priority 4: COS Queue = 4
Priority 5: COS Queue = 5
Priority 6: COS Queue = 6
Priority 7: COS Queue = 7

Table of Contents