$\wx,\wy\cr\lf
$
Fixed text
\wx
Wind speed average, x component
\wy
Wind speed average, y component
\cr
CR (carriage return)
\lf
LF (line feed)
Example
$-00.04,00.07<cr><lf>
Interpretation of the example message:
• Wind speed, average, x component: -0.04
• Wind speed, average, y component: 0.07
5.10.2.3 WMT700 Data Message 23
WMT700 Data Message 23 reports wind measurement and self-diagnostics data in the
following format:
$\ws,\wd,\wp,\wm,\Ts,\vh,\vi,\ta,\er\cr\lf
$
Fixed text
\ws
Wind speed, average
\wd
Wind direction, average
\wp
Wind speed, maximum
\wm
Wind speed, minimum
\Ts
Sonic temperature
\vh
Heater voltage
\vi
Supply voltage
\ta
Transducer temperature
\er
Status code. The code is a decimal number. Each bit corresponds to a status flag. See 5.9.2
Status Flags (page 113).