EasyManua.ls Logo

Vaisala WINDCAP WMT700 Series - 5.27 SDI-12 Data Messages; 5.27.1 WS425 A;B SDI-12 Message for C and M Command

Vaisala WINDCAP WMT700 Series
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
aI!
a
Single-digit WMT700 address that corresponds to the first character of the address
value
I
Send identification command
!
Terminates the command
The response:
allccccccccmmmmmmvvvxxx . . . xxx<CR><LF>
a
Single-digit WMT700 address that corresponds to the first character of the address
value
11 SDI-12 version number, indicating SDI-12 version compatibility; for example, version 1.1 is
encoded as 11
cccccccc 8-character vendor identification Vaisala
mmmmmm 6 characters specifying the model number of WMT700
vvv 3 characters specifying the firmware version 604
xxx ... xxx Optional field, up to 13 characters, used for a serial number or other specific WMT700
information that is not relevant for operation of the data recorder (not used)
<CR><LF> Terminates the response
5.26.1.7 aM! — Start Measurement
This command starts measurement. WMT700 does not return measurement data after this
command. It sends a response that indicates when the measurement result can be retrieved
using the aD0! command and the number of parameters.
aM!
a
Single-digit WMT700 address that corresponds to the first character of the address
value
M Start measurement command
! Terminates the command.
The response:
WMT700 User Guide M211095EN-H
158

Table of Contents

Other manuals for Vaisala WINDCAP WMT700 Series

Related product manuals