atttn<CR><LF>
a Single-digit WMT700 address that corresponds to the first character of the address
value
ttt Period of time, in seconds, after which WMT700 has the measurement ready
n Number of measurement values WMT700 calculates and returns as a response to one or
more subsequent aD0! commands
<CR><LF> Terminates the response.
Example
1M! 10025<CR><LF>
Interpretation of the example message:
Time after which the measurement is ready: 2 seconds
Number of returned measurement values: 5
To fetch the measurement results, use the aD0! command.
5.26.1.8 aV! — Start Verification
This command starts verification. However, WMT700 does not return verification data
directly after this command. It sends a response that specifies when the verification results
can be retrieved using the aD0! command and the number of parameters. The WMT700
verification data includes a watchdog count, sensor measurement unit settings, and the
current SDI mode setting.
The command:
aV!
a
Single-digit WMT700 address that corresponds to the first character of the address
value
V
Starts verification command
!
Terminates the command
The response:
atttn<CR><LF>
Chapter 5 – Operation