Parameter Name Default
Value
Allowed Values Units Description
com2_interf
0 0 = RS-485
1 = RS-422
2 = SDI-12
3 = RS-232
Interface for serial port COM2.
(The interface for serial port
COM1 cannot be changed.)
com1_paritycom2_parity
0 0 = None
1 = Even
2 = Odd
Parity for serial ports COM1
and COM2.Changes take eect
only after reset or the RESET
command.
com1_protocol
0 0 … 11 Protocol for serial port COM1.
0 = WMT700
2 = WS425 F/G ASOS
3 = WS425 A/B ASCII
4 = WS425 A/B NMEA
Standard
5 = WS425 A/B NMEA
Extended
6 = WS425 A/B WAT11
8 = MES12
11 = WMT700 NMEA MWV
com2_protocol
0 0 … 11 Protocol for serial port COM2.
1 = SDI-12
2 = WS425 F/G ASOS
3 = WS425 A/B ASCII
4 = WS425 A/B NMEA
Standard
5 = WS425 A/B NMEA
Extended
6 = WS425 A/B WAT11
8 = MES 12
11 = WMT700 NMEA MWV
com1_stopcom2_stop
1 1 = 1 bit
2 = 2 bits
Stop bits for serial ports COM1
and COM2. Changes take
eect only after reset or the
RESET command.
freqType
0 0 = Push-pull
1 = Active pull-
down
2 = Active pull-
up
AOUT1 frequency output type.
Setting 1 requires external pull-
up resistor. Setting 2 requires
external pull-down resistor.
heaBMaxPower
150 0 = O
150 = On
W heaBMaxPower sets
maximum body heater power.
Setting the parameter value to
0 disables WMT700 body
heating.
Appendix D – Configuration Parameter Descriptions