Model Code Page
34. Autocontrol ---III
15. 6. 1992
6100E, 8100E
343 3
Error messages in Service Program
Service Program has the following error messages which appear in the MESSAGE WINDOW in the RH side lower corner of the
fault tracing chart. If other error messages appear, switch off current and start from the beginning.
ERROR IN CHECKSUM If this message appears on the PC display when you are programming the AC---III unit, You
must start from the beginning after switching off and on current.
PARAMETER REV MISMATCH. Parameter file and EPROM have different version numbers.
ERROR IN EPROM If You have found an error in EPROM, switch off the AC---III unit for a while and start the
Service Program and try again programming. If this is not enough, change the central
processing unit (ECS). (EPROM=eraseable and programmable read only memory)
AC ---III DOES NOT RESPOND Connection between the PC and the AC---III unit does not function. Check the middle cable
and check that the AC---III unit is switched on. Check AC---III fuses.
ERROR IN COMMUNICATION Switch off the AC---III unit for a while and start the Service program again.
WRONG NUMBER OF CHAR This message appears if You try to copy into the AC---III unit a parameter file which has not
correct number of characters. Program error.
ILLEGAL CHAR FOUND A parameter file includes an illegal character/characters. Only figures 0---9 are allowed.
Program error.
FILE ERROR If the file does not exist, appears this message on the PC display. Check the parameter file
name. Start from the beginning after turning current off and on.