Answer to question P H --- n :
E51032 *S
6000:15:10
PH: 10 BAR
6000:15:00
PH: 18 BAR
6000: 14:50
PH: 19 BAR
6000: 14:40
PH: 16 BAR
6000:14:30
PH:10 BAR
Serial number, running mode and log identifier.
Time of measurement n: hours, minutes, seconds
Measuring value in bars
Empty line
Time of measurement n---1
Measuring nr n---1 value in bars
Empty line
Time of measurement n---2
Measuring nr n---2 value in bars
a.s.o.
Answer to question P H --- H :
Answer to question P H --- n --- A :
E51032 *A
6000:15:10
PH: 10 BAR
6000:15:00
PH: 18 BAR
6000: 14:50
PH: 19 BAR
6000: 14:40
PH: 16 BAR
6000:14:30
PH:5 BAR
E51032 *S
6025:23:10
MAX
6000:15:00
PH: 21 BAR
Maximum value from standard log
Answer to question P H --- L :
E51032 *S
6025:23:10
MIN
6000:15:00
PH: 4 BAR
Answer to question PH ---PH:
E51032 *
6025:23:10
MAX PEAK
5253:27:30
PH: 23 BAR
Maximum
value from
maximum/
minimum log
Answer to question PH ---PL:
E51032 *
6025:23:10
MIN PEAK
3200:00:10
PH: 1 BAR
Minimum
value from
maximum/
minimum log
Serial number, running mode and log identifier.
Current running hours
Time of masurement
Current running
hours
Time of measurement
Pressure value
Minimum
value from
standard log
444
Model Code Page
31. CareTel
1. 4. 1997
6000--8750 360 4
Answers
In the answer of one value there is always the tractor serial number in the beginning (fed into the data logger in the factory). In
the same line, there is an asterisk, if the engine is running and a log identifier, in which S=standard log, A=alarm log and
E=special tracking log.
The measuring frequency has been set in the factory. The frequency below is 10 seconds.