T O [ --- n ] [ --- A ]
--- n =which value in order from the last value backwards (1---195 values in memory)
--- A =query is directed to the alarm log. If ---A is not given, the query is directed to the standard log.
Answers
Exsamples
Answer to question T O --- n
E51032 *S
6025:23:10
6000:15:10
TE: 92 C
TT: 80 C
ME:80
RE:2000 RPM
RP: 1000 RPM
PH: 18 BAR
PT: OK
PE: OK
SP:OFF
Serial number, running mode, log identifier
Current running hours
Time of measurement n
Engine temperature
Sigma---Power (8750 only)
Answer to question T O --- n --- A
E51032 *A
6025:23:10
5600:14:20
TE: 92 C
TT: 80 C
ME:80
RE:2000 RPM
RP: 1000 RPM
PH: 10 BAR
PT: OK
PE: OK
SP:OFF
C. Query of number of exceeding times of warning limits
W A [ --- H | --- L ]
--- H =exceeding of upper limits
--- L =undershoot of lower limits
If these parameters are not given, CareTel shows the exceeding of the upper limits.
Answers
Exsamples
Answer to question WA
E51032 *
6025:23:10
WARNINGS
CHHOUR PCS
TE 5600:120
TT 2100:5
ME 0000:0
RE 5600:120
RP 2020:1
PH 1800:212
PT 0120:1
PE 0111:1
SP 2100:1
Exceedings of warning limits
Channel, hours, pcs, heading line
Engine temperature, the last
exceeding time and number of
exceedings
a.s.o.
Transmission temperature
Moment engine (8750 only)
Engine revs
PTO shaft revs
Low pressure circuit pressure
Transmission oil pressure
Engine oil pressure
445
Model Code Page
31. CareTel
1. 4. 1997
6000--8750 360 5
B. Query of all measurements