DCOB System Attributes (PGM 186) 1-99
Chapter 1: SBX IP Online PC Admin
SBX IP - PC Admin Guide
DCOB System Attributes (PGM 186)
ITEM RANGE DEFAULT REMARK
DCOB CO Type
(This is actually
programmed in PGM187,
BTN4)
0-2 2 0: Sweden/Cyprus
1: Italy
2: Korea/Australia
Metering Type 0-1 0 0: Not used
1: When a Metering signal is received
R2 OUT Manage Timer 01-50 14
(sec)
In R2 signaling, maximum time for waiting for forward
signal from PX
R2 IN Manage Timer 01-50 14
(sec)
In R2 signaling, maximum time for waiting for forward
signal from PX
R2 Disappear Timer 01-50 14
(sec)
--
R2 Pulse Timer 01-30 07
(20ms)
In R2 signaling, time duration to send pulse typed R2
signal
R2 Ready Timer 000-500 007
(20ms)
--
Dial Tone Delay Timer 01-30 20 --
Line Status 1-9 6 Free Line
Calling Category 1-9 1 User no priority
ANI Request ON/OFF OFF ON: Caller ID Service
CLI Digits Number 01-10 04 --
R2 Out Digits Timer 01-50 05 --
R2 Error Prompt ON/OFF OFF --
R2 Busy Prompt ON/OFF OFF --
R2 Annc Prompt Usage ON/OFF OFF --
DCO Gain 01-63 32 --