CO Related Admin (PGM 140/141/142/143/146/147) 1-55
Chapter 1: SBX IP Online PC Admin
SBX IP - PC Admin Guide
CO Tenancy
Group
0-5 5 Tenancy Group of CO line.
Emergency
911 Usage
ON/OFF By
default,
CO Line
01 is ON
and other
CO Lines
are OFF.
If this value is set to ON, the designated
CO Line is active for E911 use.
CO Line Attributes II (PGM142)
ITEM RANGE DEFAULT REMARK
CO Line
Name Display
ON/OFF OFF If CO Line name is assigned at BTN2, and
this field is ON, CO name is displayed for
CO incoming calls
CO Line
Name Assign
Max 12
characters
-- --
Metering Unit 00-06 00 There are 7 metering signal types:
- 0: None
- 1: 50 Hz
- 2: 12 KHz
- 3: 16 KHz
- 4: Singular Polarity Reverse (SPR)
- 5: Plural Polarity Reverse (PPR)
- 6: No Polarity Reverse (NPR)
Line Drop
Using CPT
ON/OFF OFF If this field set to ON, CPT checks the
incoming CO line when answered and if
CPT detects dial tone, then the system
drops the line for toll restriction.
CO Distinct
Ring
0-4 0 The CO can have a specific ring signal to
stations in the system through this field’s
setting. This ring type can be programmed
at PGM422.
CO Line Attributes I (PGM141)
ITEM RANGE DEFAULT REMARK