Chapter 7 Maintenance ALPHA V40
Version 18.07.06
101
Six-month Maintenance
1. Replace the air filter elements and clean the filter bowl.
NOTE: Do not use air pressure from the shop air supply to blow dust from the machine.
There is a possibility that this air can contain water and emulsified oil, which can damage
the electrical components in your machine.
2. Clean the inside and outside of the machine enclosure using an industrial vacuum
cleaner.
3. Check the tamp home/extend sensor adjustment. Refer to Tamp Home/Extend Sensor
Adjustment, as of page 43.