Status Code Entry Chart (cont.)
Status
Code
LL-11
LL-12
LL-21
LL-22
LL-30
LL-41
Description
Communications error
Failed communications between the Driver
PWB (A2) and the Main PWB (A3).
Photoreceptor motor stall fault
HVPS Charge error
The charge scorotron fault signal was active
for 1.5 seconds.
Transfer / Detach HVPS Charge error
The transfer / detach corotron fault signal
was active for 1.5 seconds.
Cutter error
The cutter did not leave or reach the home
sensor. Turn power off, then on.
Fuser error
The fuser did not reach 110°F within one
minute.
Components
Driver PWB (A2) (fuser drive circuit)
Driver PWB (A2) (drum drive circuit)
Main PWB (A3)
CAUTION: Fuser must be up to
temperature before running motors.
Drum drive motor (A20MOT3)
Driver PWB (A2)
ADJ 8.4 Media Transport
Xerographic HVPS (A25)
Driver PWB (A2)
Scorotron
Xerographic HVPS (A25)
Driver PWB (A2)
Transfer/Detack Corotron
Cutter home sensor (A8Q1)
Driver PWB (A2)
Cutter Drive Motor
Fuser heat rod (HTR1)
Thermistor assembly (A23RT1)
Fuser power relay (K1)Triac (Q1)
AC Power module (A1)
Driver PWB (A2)
Main PWB (A3)
RAP
NO
NO
NO
NO
NO
YES
Comp
Code
[0403]
[0403]
[1004]
BSD Ref
4.1
4.3
4.3
9.1
9.8
7.5
10.1
PL
Ref
PL 1.1
PL 1.3
PL 1.1
PL 1.3
PL 1.1
PL 14.3
PL 1.1
PL 10.4
PL 1.2
PL 1.3
Status Code Entry Chart
1/98
1-14
8830