23. (Figure 11): Reinstall the PMC PWB onto the 8830 Controller MCB.
B
Reinstall three screws,
three lock washes and
one clamp.
Transfer NIC guide
rail (if missing)
NOTE: Not all of the MCB and PMC PWB connectors can be reattached at this time, due
to the need to food several of them through openings in the 8830 Printer Right Lower
Cover in the final steps of this procedure.
27. (Figure 12): Note the location of the Scanner and Ul Power Harness connectors on the
new 8830 Controller Connector Panel. (Do not attempt to route the harnesses yet.)
Scanner Harness
Ul Power Harness (routes to 8830
DOS Control Panel)
Reinstall VPI connector
Figure 12 Signal and Ul Power Harnesses on 8830 Controller Connector Panel
NOTE: In the following step the Scanner harness will replace the ribbon cable previously
attached to J5 on the MCB.
Guide PMC PWB Into slot on Connector
panel, then lower It Into connectors on
MCB. Secure on Connector Panel with two
screws
Figure 11 Remounting the PMC PWB
24. Reattach plugs P11, and P12 to J11 and J12 on the MCB prior to performing the next
step. (See Figure 11 for location).
25. Lower the MCB / Connector Panel Plate back on to the 8830 Controller Chassis.
26. Replace the 6 screws on the front of the Controller Chassis that attach the Controller
Chassis to the Connector Panel Plate.
8830 DDS
3/98
6-33
General Procedures
installation of Tags 7 and 8
D
C