EasyManua.ls Logo

Xerox ColorQube 9301 - Page 629

Xerox ColorQube 9301
1812 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
February 2013
2-605
ColorQube® 9303 Family
OF 5
Status Indicator RAPs
NOTE: On Application power up the 7-segment display cycles around displaying these codes
until the relevant platform has fully synchronized with the system. Any code left displayed after
power up indicates this event has not been detected in software and is a probable s/w issue
Figure 1 Single board controller PWB
System memory 2 Flashing Failed system memory Install a new System
memory PWB, PL 3.11
Item 4
EPC Memory 3 Flashing Failed EPC memory Install a new EPC memory
PWB, PL 3.11 Item 21
NVM and RTC
Module
4 Flashing Failed NVM memory Install a new NVM mod-
ule PWB, PL 3.11 Item 17
Flash Module 5 Flashing Failed flash memory Flash module. Install a
new SBC PWB, PL 3.11
Item 13.
External Hard Drive 6 Flashing Failed external hard
drive
Install a new External hard
drive, PL 3.11 Item 2
RTC module 7 Flashing Failed RTC RTC module. Install a new
SBC PWB, PL 3.11 Item
13.
Initial entry to ker-
nel code
0 Flashing Waiting for power normal No action, no POST fault
detected
U-boot complete 9 Flashing U-boot hand over con-
trol to kernel
Kernel software
Kernel starting user
space
U Flashing Kernel starting user
space
Kernel / run time software
Machine in ready
mode
Blank Flashing None, no fault detected No action, no fault
detected
UI platform avail-
able
A Flashing UI platform available See NOTE
IIT comms estab-
lished
b Flashing IIT comms established See NOTE
NC platform avail-
able
C Flashing NC platform available See NOTE
Dc platform avail-
able
d Flashing Dc platform available See NOTE
IOT comms estab-
lished
E Flashing IOT comms established See NOTE
Fax comms estab-
lished
F Flashing Fax comms established
Only if Fax installed
See NOTE
Machine attempt-
ing sleep entry
L Flashing OS suspending drivers,
entering sleep
(Split power plane TBC)
None, for diagnostic infor-
mation only information
only
Machine in sleep
state
r Flashing Resting in sleep None, for diagnostic infor-
mation only
Machine in semi-
conscious state
t Flashing Running in semi-con-
scious mode
None, for diagnostic infor-
mation only
Table 2 7-Segment LED display
POST code name
Fault
code
Decimal
point
status Code Description Service action
Machine attempt-
ing sleep wake-up
H Flashing OS resuming drivers None, for diagnostic infor-
mation only information
only
Table 2 7-Segment LED display
POST code name
Fault
code
Decimal
point
status Code Description Service action

Table of Contents

Other manuals for Xerox ColorQube 9301

Related product manuals