3.4 Motion Parameter Details
3.4.2 Setting Parameter Details
3-62
Number of POSMAX Turns Preset Data
Set the preset value to set in the IL1E monitor parameter (Number of POSMAX Turns)
when bit 6 (Number of POSMAX Turns Preset Request) in the OW00 setting parameter
changes to 1 (ON).
Setting Precautions
This parameter is not valid for linear motors.
Refer to the following section for details on the use of the coordinate system settings.
5.2 Absolute Encoders on page 5-17
SERVOPACK User Monitor Setting
SERVOPACK User Monitor Setting
Bits 4 to 7: Monitor 2
Select the SERVOPACK information to report in the IL30 monitor parameter (SERVO-
PACK User Monitor 2) from the following list.
0: APOS (feedback position).
1: CPOS (reference position).
2: PERR (position deviation).
3: LPOS1 (latch position 1).
4: LPOS2 (latch position 2).
5: FSPD (feedback speed).
6: CSPD (reference speed).
7: TRQ (torque/force reference).
8: ALARM (detailed information on the first alarm).
If an alarm occurs after a warning, the alarm is given.
9 to B: Reserved.
C: CMN1 (common monitor 1).
The monitor data that is specified in common parameter No. 89 is reported.
For details on the contents of monitor data, refer to information on the SERVOPACK common
parameter No. 89.
D: CMN2 (common monitor 2).
The monitor data that is specified in common parameter No. 8A is reported.
For details on the contents of monitor data, refer to information on the SERVOPACK common
parameter No. 8A.
E: OMN1 (optional monitor 1).
The monitor data that is specified in the parameter is reported. The monitor data depends on
the product specifications.
F: OMN2 (optional monitor 2).
The monitor data that is specified in the parameter is reported. The monitor data depends on
the product specifications.
Register
Address
Name
Setting
Range
Setting Unit Default Control mode
OL4C
Number of POSMAX Turns Pre-
set Data
-2
31
to 2
31
1
rev 0
Register
Address
Name
Setting
Range
Setting Unit Default Control mode
OW4E
SERVOPACK User Monitor Set-
ting
−−0700H
SVC
SVR
Position
Speed
Phase
Torqu e
SVC
Position
Speed
Phase
Torqu e