7.2 MECHATROLINK Communications Settings
7.2.2 MECHATROLINK Detail Definition Dialog Box Details
7-12
PROFILE
Set the profile to use.
• Settings: Depends on the device.
BYTE
Set the number of transmission bytes.
• Settings: Depends on the profile.
INPUT
Set the first register address of the input area.
These settings are disabled if the profile is set to Standard Servo.
• Setting range: The range of the Module’s I/O registers
OUTPUT
Set the first register address of the output area.
These settings are disabled if the profile is set to Standard Servo.
• Setting range: The range of the Module’s I/O registers
D
Enable or disable the I/O registers.
• Settings: Enable or Disable
: Enabled
: Disabled
SIZE
Set the input or output size in words.
These settings are disabled if the profile is set to Standard Servo.
• Setting range: 0 to 32
SCAN
Set the scan in which the input or output is performed.
These settings are always set to High if the profile is set to Standard Servo.
• Settings: High or Low
• Comment
Enter a comment of up to 32 characters if required.
Deleting Station Assignments
You can delete the items on the Link Assignment Tab Page for a station.
Click any cell in the row for the station to delete, and then select Edit − Assignment Delete
from the menu bar.
JEPMC-MTP2910-E Standard I/O 64 125 μs8 ms
WildCard Device
Standard Servo 48
Depends on the
actual device.
Depends on the
actual device.
Standard I/O 16, 32, 48, 64
Depends on the
actual device.
Depends on the
actual device.
Continued from previous page.
DEVICE
Communications Specifications
Supported Profiles
Number of Trans-
mission Bytes
Minimum Trans-
mission Cycle
Maximum Trans-
mission Cycle