10.4 Main Commands and Subcommands
10.4.3 Main Command Details
10-26
Alarm History Monitor
Description
Reads the Inverter alarm history.
Setting Parameters
Monitor Parameters
User Constant RAM Writing
Description
Saves the parameter data written by executing Write User Constant in the Inverter volatile
memory to enable the data.
Setting Parameters
Name Register No. Setting Range Remarks
Command OW08 0 to 8 05: Alarm History Monitor
Inverter Alarm Monitor
Number
OW32 0 to 3 Alarm monitor number
Name Register No.
Setting
Range
Remarks
Warning IL02 Bit −
Alarm IL04 Bit −
Command Response Code IW08 0 to 8 05: Alarm History Monitor
Command Status IW09 Bit
Bit 0 (Command execution
flag)
ON during execu-
tion
Bit 3 (Command error com-
pleted status)
ON when an error
occurs during
command pro-
cessing
Bit 8 (Command execution
completed)
OFF during execu-
tion, and ON when
execution is com-
pleted.
M-III Inverter Command
Status
IL2A Bit Inverter operating status
M-III Command Status IW2C Bit Inverter command processing status
Inverter Alarm Code IW32 0 to FFFFH The alarm history that is read out.
Name Register No. Setting Range Remarks
Command OW08 0 to 8 06: User Constant RAM Writing