10.4 Main Commands and Subcommands
10.4.4 Subcommand Details
10-34
Setting Parameters
Monitor Parameters
Read Fixed Parameters
Description
Reads out the set data of the specified fixed parameter.
Setting Parameters
Monitor Parameters
Name Register No. Setting Range Remarks
Sub Command OW0A 0 to 65535 08: Transmission Reference
Transmission Reference Output
Data 16
OW70 0 to FFFFH Subcommand output data bytes 0 and 1
.
.
.
.
.
.
−−
Transmission Reference Output
Data 31
OW7F 0 to FFFFH −
Name Register No.
Setting
Range
Remarks
Subcommand Response Code IW0A 0 to 65535 08: Transmission Reference
Subcommand Status IW0B Bit
Bit 0 (Command execution
flag)
ON during
execution
Bit 3 (Command error com-
pleted status)
Always OFF
Bit 8 (Command execution
completed)
Always OFF
Transmission Reference Input
Data 16
IW70 0 to FFFFH Subcommand input data bytes 0 and 1
.
.
.
.
.
.
0 to FFFFH −
Transmission Reference Input
Data 31
IW7F 0 to FFFFH −
Name Register No. Setting Range Remarks
Sub Command OW0A 0 to 65535 09: Read Fixed Parameters
Fixed Parameter Number OW48 0 to 63 Set the fixed parameter number.
Name Register No.
Setting
Range
Remarks
Subcommand Response
Code
IW0A 0 to 65535 09: Read Fixed Parameters
Subcommand Status IW0B Bit
Bit 0 (Command execution
flag)
ON during execu-
tion
Bit 3 (Command error com-
pleted status)
ON when an error
occurs during
command pro-
cessing.
Bit 8 (Command execution
completed)
OFF during exe-
cution, and ON
when execution
is completed.
Fixed Parameter Monitor IL48
-2
31
to 2
31
−1
−