10.5 Motion Parameter Details
10.5.2 Setting Parameter List
10-37
OW01
Mode Set-
tings 1
Bit 0: Multi-function
Input Terminal 3
0: Function OFF, 1: Function ON
Specifies whether to use the multi-function input
terminals. The status of the input terminals is
reported in the Multi-Function Input Terminal moni-
tor parameter.
Bit 1: Multi-function
Input Terminal 4
Bit 2: Multi-function
Input Terminal 5
Bit 3: Multi-function
Input Terminal 6
Bit 4: Multi-function
Input Terminal 7
Bit 5: Multi-function
Input Terminal 8
Bits 6 to F Reserved
OW
02
to
OW05
− Reserved
OL06 (Inverter command output) Reserved
OW
08
Command
10.4.3 Main Command Details on page
10-21
00: No Command
01: Inverter Drive Control
02: Read User Constant
03: Write User Constant
04: Alarm Monitor
05: Alarm History Monitor
06: User Constant RAM Writing
07: User Constant EEPROM Writing
08: Transmission Reference
OW
09 − Reserved
OW0A
Sub Command
10.4.4 Subcommand Details on page
10-28
00: No Command
01: Inverter I/O Control
02: Read User Constant
03: Write User Constant
04: Alarm Monitor
05: Alarm History Monitor
06: Reserved
07: Reserved
08: Transmission Reference
09: Read Fixed Parameters
OW
0B − Reserved
Continued on next page.
Continued from previous page.
Register No. Name Description