10.5 Motion Parameter Details
10.5.2 Setting Parameter List
10-45
OW47
Auxiliary Inverter User Constant
Set Point 4
Setting range: 0 to 65,535 (FFFFH)
Set the data to write for the Write User Constant
subcommand.
Enabled when Auxiliary Inverter User Constant
Number Size = 4.
OW
48 Fixed Parameter Number
Setting range: 0 to 65,535
Set the fixed parameter number to read for the
Read Fixed Parameters subcommand.
OW
49
to
OW5F
– Reserved
OW
60 Transmission Reference Output Data 0
Setting range: 0 to FFFFH
This data is sent as the 1st word in the command
(main command bytes 0 and 1) when the Transmis-
sion Reference command is executed.
OW
61 Transmission Reference Output Data 1
Setting range: 0 to FFFFH
This data is sent as the 2nd word in the command
(main command bytes 2 and 3) when the Transmis-
sion Reference command is executed.
OW
62 Transmission Reference Output Data 2
Setting range: 0 to FFFFH
This data is sent as the 3rd word in the command
(main command bytes 4 and 5) when the Transmis-
sion Reference command is executed.
OW
63 Transmission Reference Output Data 3
Setting range: 0 to FFFFH
This data is sent as the 4th word in the command
(main command bytes 6 and 7) when the Transmis-
sion Reference command is executed.
OW
64 Transmission Reference Output Data 4
Setting range: 0 to FFFFH
This data is sent as the 5th word in the command
(main command bytes 8 and 9) when the Transmis-
sion Reference command is executed.
OW
65 Transmission Reference Output Data 5
Setting range: 0 to FFFFH
This data is sent as the 6th word in the command
(main command bytes 10 and 11) when the Trans-
mission Reference command is executed.
OW
66 Transmission Reference Output Data 6
Setting range: 0 to FFFFH
This data is sent as the 7th word in the command
(main command bytes 12 and 13) when the Trans-
mission Reference command is executed.
OW
67 Transmission Reference Output Data 7
Setting range: 0 to FFFFH
This data is sent as the 8th word in the command
(main command bytes 14 and 15) when the Trans-
mission Reference command is executed.
OW
68 Transmission Reference Output Data 8
Setting range: 0 to FFFFH
This data is sent as the 9th word in the command
(main command bytes 16 and 17) when the Trans-
mission Reference command is executed.
OW
69 Transmission Reference Output Data 9
Setting range: 0 to FFFFH
This data is sent as the 10th word in the command
(main command bytes 18 and 19) when the Trans-
mission Reference command is executed.
OW
6A Transmission Reference Output Data 10
Setting range: 0 to FFFFH
This data is sent as the 11th word in the command
(main command bytes 20 and 21) when the Trans-
mission Reference command is executed.
OW
6B Transmission Reference Output Data 11
Setting range: 0 to FFFFH
This data is sent as the 12th word in the command
(main command bytes 22 and 23) when the Trans-
mission Reference command is executed.
Continued on next page.
Continued from previous page.
Register No. Name Description