10.5 Motion Parameter Details
10.5.2 Setting Parameter List
10
Inverter Operation
10-47
* Communications are continued when the fixed parameters in the SVC Function Module are set as follows:
When Communication Abnormality Detection Mask is enabled in Function Selection Flag 2
When Communication Abnormality Detection Mask is disabled in Function Selection Flag 2 and Warning is
selected for Communication Selection Is Abnormal in Function Selection Flag 3
OW78 Transmission Reference Output Data 24
Setting range: 0 to FFFFH
This data is sent as the 9th word in the subcom-
mand (subcommand bytes 16 and 17) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
OW79 Transmission Reference Output Data 25
Setting range: 0 to FFFFH
This data is sent as the 10th word in the subcom-
mand (subcommand bytes 18 and 19) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
OW7A Transmission Reference Output Data 26
Setting range: 0 to FFFFH
This data is sent as the 11th word in the subcom-
mand (subcommand bytes 20 and 21) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
OW7B Transmission Reference Output Data 27
Setting range: 0 to FFFFH
This data is sent as the 12th word in the subcom-
mand (subcommand bytes 22 and 23) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
OW7C Transmission Reference Output Data 28
Setting range: 0 to FFFFH
This data is sent as the 13th word in the subcom-
mand (subcommand bytes 24 and 25) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
OW7D Transmission Reference Output Data 29
Setting range: 0 to FFFFH
This data is sent as the 14th word in the subcom-
mand (subcommand bytes 26 and 27) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
OW7E Transmission Reference Output Data 30
Setting range: 0 to FFFFH
This data is sent as the 15th word in the subcom-
mand (subcommand bytes 28 and 29) when the
Transmission Reference subcommand is executed.
Note: Valid only in 64-byte Mode.
OW7F Transmission Reference Output Data 31
Setting range: 0 to FFFFH
This data is sent as the 16th word in the subcom-
mand (subcommand bytes 30 and 31) when the
Transmission Reference subcommand is executed.
Note: Valid only in 64-byte Mode.
Continued from previous page.
Register No. Name Description