10.5  Motion Parameter Details
 10.5.3  Monitor Parameter List
10-49
IL04 Alarm
Bits 0 to E Reserved
Bit F: User Constant Error Not used
Bit 10: Synchronization 
Communication Error
Turns ON when a MECHATROLINK communica-
tions watchdog timer timeout error is detected.
Enabled when the WDT Abnormality Detection 
Mask bit of the Function Selection Flag 2 fixed 
parameter is set to Disabled.
This alarm can be cleared by executing Alarm 
Clear.
Bit 11: Communication 
Error
Turns ON when MECHATROLINK communica-
tions errors are detected continuously.
Communication Abnormality Detection Mask bit 
of the Function Selection Flag 2 fixed parameter 
is set to Disabled, and Alarm is selected for 
Communication Selection Abnormal of the Func-
tion Selection Flag 3 fixed parameter.
This alarm can be cleared by executing Alarm 
Clear.
Bit 12: Communication
Timeout Error
Turns ON when a response from the Inverter for a 
command or subcommand is not detected within 
five seconds.
This alarm can be cleared by executing Alarm 
Clear.
Bits 13 to 15 Reserved
Bit 16: Scan Setting Error
Turns ON while the high-speed scan cycle setting 
and the MECHATROLINK communications cycle 
setting are asynchronous.
Bits 17 to 1B Reserved
Bit 1C: Cyclic Communi-
cation Initialize incomplete
With MECHATROLINK-III, a node can join the 
network while communications are in progress. 
However, conditions such as the transmission 
cycle and the number of slave stations may pre-
vent a node from joining the network. If that 
occurs, this bit turns ON. If this alarm occurs, 
turn the power supply to the MP3000 OFF and 
ON again or reset the network (OW00 bit 
C).
Bit 1D: Drive Type Error
Turns ON when the Inverter model assigned in 
the SVC definitions does not match the actual 
Inverter model that is connected.
Bits 1E to 1F Reserved