10.5 Motion Parameter Details
10.5.5 Inverter Input Data Details
10
Inverter Operation
10-61
IW1D
Multi-Function
Input Terminal
Bit 0: Terminal 1
Status
0: OFF, 1: ON
Bit 1: Terminal 2
Status
0: OFF, 1: ON
Bit 2: Terminal 3
Status
0: OFF, 1: ON
Bit 3: Terminal 4
Status
0: OFF, 1: ON
Bit 4: Terminal 5
Status
0: OFF, 1: ON
Bit 5: Terminal 6
Status
0: OFF, 1: ON
Bit 6: Terminal 7
Status
0: OFF, 1: ON
Bit 7: Terminal 8
Status
0: OFF, 1: ON
Bits 8 to F Reserved
IW1E Analog Input A1 Unit: 0.1%
IW1F Encoder Count PG2
Unit: pulse
(Valid when a PG-Y2 is connected.)
IW20 Monitor data set in F6-23
Reports the result of the monitoring set in the F6-23
Inverter parameter.
IW21 Monitor data set in F6-24
Reports the result of the monitoring set in the F6-24
Inverter parameter.
Continued on next page.
Continued from previous page.
Register No. Name Description