11.3 MECHATROLINK-III I/O Module Settings
11.3.4 I/O Command Details
11-24
Confirming Completion of the Command
Use the following information to confirm that the command has been completed.
Write Non-volatile Parameter Command
Changes an I/O Module parameter in non-volatile memory.
Command Format
NO: Parameter Number
SIZE: Parameter Size (Bytes)
PARAMETER: Parameter Data
No. Confirmation Method
1 I/O Command Response register = 5 (Read Non-volatile Parameter)
2 Command Status bit 2 (CMDRDY) = 1
3 NO must be the same in the command and response.
4 SIZE must be the same in the command and response.
1. If the command is not completed within 5 seconds after it is executed, bit 0 in the Master Sta-
tus register changes to 1 (TIMEOUT).
2. When bit 0 (D_ALM) or bit 1 (D_WAR) in the Command Status register is 1, check the error
details with the application and perform the stop processing. The system will not perform stop
processing.
Some I/O Module devices do not support the Write Non-volatile Parameter command. Refer to
the product specifications of the I/O Module for details.