3.3 Motion Parameter Tables
3.3.2 Setting Parameter Table
3-12
OW05
Function Set-
tings 3
Bit 0: Reserved.
page 3-41
Bit 1: Disable Phase Reference Calcu-
lation
0: Enabled, 1: Disabled
Bit 2: External Positioning Final Travel
Distance Write Selection
0: Automatically apply
1: Do not automatically apply
Bits 3 to A: Reserved.
Bit B: Zero Point Return Input Signal
0: OFF, 1: ON
Bits C to F: Reserved.
OW
06
M-III Vendor-
specific Servo
Command Out-
put Signal
This parameter is used as a vendor-
specific output area.
page 3-42
OW
07 Reserved.
Continued on next page.
Continued from previous page.
Register
Address
Name Description
SVC
Function
Module
SVR
Function
Module
Reference
Page