18-24
IM 701240-01E
Item Specifications
Common mode rejection [Voltage measurement] 80 dB or more (50/60 Hz) (typical
6
)
ratio [Temperature measurement] 120 dB or more (50/60 Hz, with 2-Hz filter ON, signal source
resistance of 500 Ω or less) (typical
6
)
Residual noise level [Voltage measurement] ±100 µV or ±0.1% of range, whichever is greater (typical
6
)
(Input section shorted)
A/D conversion resolution [Voltage measurement] 16 bits (24000 LSB/range)
Temperature coefficient [Voltage measurement] Zero point: ±(0.01% of range)/°C (typical
6
)
Gain: ±(0.02% of range)/°C (typical
6
)
Reference junction compensation accuracy (when the input terminal temperature is balanced)
K, E, J, T, L, U, N: ±1°C
R, S, B, W: ±1.5°C
Au7Fe: ±1K
Bandwidth limit [Temperature measurement] (digital filter + analog filter)
Select from OFF, 30 Hz, 8 Hz, and 2 Hz + 150 Hz secondary analog filter
[Voltage measurement] Select from OFF, AUTO, 4 kHz, 400 Hz, and 40 Hz.
Cutoff characteristics: –12 dB/OCT (typical
6
, setting other than AUTO)
Cutoff frequency (fc) when set to AUTO (only on the 701262)
Sample Rate Cutoff Frequency (fc)
100 kHz or higher 40 kHz
100 Hz to 50 kHz 40% of the sample rate
50 Hz or lower 20 Hz
Cutoff characteristics during AUTO: –65 dB at 2×fc (typical
6
)
Table of cutoff frequency characteristics of the anti-aliasing filter (AAF)
When the filter is set to Auto, the anti-aliasing filter and low-pass filter are automatically set
according to the sample rate.
Sample Rate AAF Low-Pass Filter
100 kS/s 40 kHz OFF
50 kS/s 20 kHz OFF
20 kS/s 8 kHz OFF
10 kS/s 4 kHz 4 kHz
5 kS/s 2 kHz 4 kHz
2 kS/s 800 Hz 4 kHz
1 kS/s 400 Hz 400 Hz
500 S/s 200 Hz 400 Hz
200 S/s 80 Hz 400 Hz
100 S/s 40 Hz 40 Hz
50 S/s 20 Hz 40 Hz
20 S/s to 5 S/s 20Hz 40 Hz
2 S/s or less 20 Hz 40 Hz
Ext sample 40 kHz OFF
1 Value measured under standard operating conditions (section 18.11).
2 Does not include the reference junction temperature compensation accuracy.
3 This module supports Au7Fe with 0.07% metal content with respect to gold.
H
L
5
4
6 Typical value represents a typical or average value. It is not strictly warranted.
WARNING
• Do not apply input voltage exceeding the maximum input voltage or allowable
common mode input voltage.
• To prevent electric shock, be sure to furnish protective earth grounding of the SL1400.
• To prevent electric shock, be sure to fasten the module screws. Otherwise, the
electrical and mechanical protection functions will not be activated.
18.12 Module Specifications