AutoTest Sytem Operation
Subject to Export Control, see Cover Page for details.
5-12
4 = FM 750 us
5 = AM USB
6 = AM LSB
set_rfgen_level [ level in dBm ]
Sets generator level in dBm and sends rfgen level command to generator sub-system.
Format: Decimal level values in dBm
set_rfgen_port [ port 0/1 ]
Sets generator port and sends rfgen port command to generator sub-system.
Valid states are:
0 = T/R
1 = GEN
set_rfgen_enable [ state 0/1 ]
Enables/Disables generator and sends rfgen enable command to generator sub-system.
Valid states are:
0 = Disabled
1 = Enabled
set_rfgen_offseten [ state 0/1 ]
Turns generator offset ON/OFF and sends rfgen leveloffseten command to the generator sub-
system.
Valid states are:
0 = OFF
1 = ON
set_rfrec_port [ port 0/1 ]
Sets receiver port and sends receiver port command to receiver sub-system.
Valid ports are:
0 = T/R
1 = ANT
set_rfrec_offseten [ state 0/1 ]
Turns analyzer Top of Scale offset ON/OFF and sends analyzer offseten to analyzer sub-
system.
Valid states are:
0 = OFF
1 = ON
set_agclevel_mode [ state 0/1 ]
Sets AGC Level mode of operation.
Valid states are:
0 = Manual
1 = Auto
set_agclevel_value
Sets AGC level when mode is set to Manual.
Format: Decimal value in dBm