Analog Duplex System
Subject to Export Control, see Cover Page for details.
8-45
Harmonics and Spurious Measurements Option Tile
The Harmonics and Spurious Test Option (390XOPT060) provides users with the ability to examine
incremental readings at the 2nd and 3rd harmonics at a specified frequency and to obtain readings
at the highest non-harmonic frequency spike over a defined frequency range. The Harmonics and
Spurious Measurements Tile is only available when the Harmonics and Spurious Test Option
(390XOPT060) is installed in the Test Set.
Fig. 8-41 Analog Duplex - Harmonics and Spurious Measurements Tile
Field/Soft Key Definitions
Fundamental Frequency
Sets the frequency at which Harmonic measurements are obtained.
Fundamental Level
Sets the unit of measurement for Harmonic measurements.
Second Harmonic Level
Indicates reading at second harmonic level.
Third Harmonic Level
Indicates reading at third harmonic level.
[Start] Soft Key
Starts harmonic and spurious measurement sweeps.